Meta Hawk III series

Pipe transfer type metal detector

Pipe transfer type metal detector

specifications

 

Model SD3-100RW-1.0S SD3-100RW-1.5S SD3-100RW-2.0S SD3-100RW-2.5S SD3-100RW-3.0S
Detection
sensitivity
Fe φ0.4mm
SUS304 φ0.7mm
Inside diameter of coil opening  φ100mm
Pipe size (inch) 1.0 1.5 2.0 2.5 3.0
Height of inlet/outlet 750mm
Ferrule shape IDFferrule
Max. passing flow rate (L/h)
※1
500 1200 2000 4500  7000
Withstand pressure (MPa) ※2 0.7 0.7 0.7 0.7 0.3
Heatproof temperature(℃) ※2 80 80 80 80 50
 Sorting method Air driven 3-way ball valve
Ball valve operation  Operating temperature range: -5℃ to 95℃, Max. operating pressure: 0.7 MPa, IP55
Power voltage and capacity   AC100V(50/60Hz)120VA
Operating air pressure   0.4~0.7MPa
Accessory Hook spanner, clamp
Mass(kg)  91 94  100  107  111

※1 : It is different from specific gravity or viscosity of fluid. Please ask us.
※2 : The withstand pressure may vary depending on the operating temperature. Contact System Square for further information.
※Appropriate measures are taken so that no products are brought in contact with the inside of the passage port.
The detection sensitivity may vary depending on the product and/or operating environment.
The specifications are subject to change without prior notice due to improvement.

appearance figure